SELECT DISPLAYS : BEAMS
5
02.9651.0001 C 23-Sep-02 87
Note: Since Beam selects store data according to luminaire types, if a Beam is
recalled which has no data for that luminaire type, then the channel will remain in its
previous state. When recalled, Beams are not routed through the filters.
Recall a Beam using Beams select display:
Step 1. Select required channels (only selected channels of types that have data
stored in that beam state will be affected).
Step 2. Ensure Beams are selected on at least one select display.
Step 3. Press required [Beam Select Button].
Recall a Beam using command-line keypad:
Step 1. Select required channels (only selected channels of types that have data
stored in that Beam will be affected).
Step 2. Press [Beam] [n] [Enter] (where n is the discrete Beam number).
From Select Displays Window
When storing or modifying Beams from the Select Displays, first select channels of
types to be stored in the Beam select (refer to “Selecting Channels” on page 50). Filter
parameters as required and adjust with manual control functions.
To store, label, update, delete, and recall Beams, refer to the procedures given in
“Select Displays Window” on page 80.
From Keypad
Store a new Beam:
Step 1. Select required channels.
Step 2. Using manual controls, set all required parameters.
Step 3. Filter attributes as required using Filter Display window.
Step 4. Press [Store] [Beam] [n] [Enter] or [Store] [Beam] [n] [Label] [Enter]
[xxxxxx] [return] (where n is the discrete Beam number).
Add new types to a Beam:
Step 1. Select required channels.
Step 2. Using manual controls, set all required parameters.
Step 3. Filter attributes as required using Filter Display window.
Step 4. Press [Store] [Beam] [n] [Enter] or [Store] [Beam] [n] [Label] [Enter]
[xxxxxx] [return] (where n is the discrete Beam number).
Comments to this Manuals