MENU SYSTEM : SELF TESTS
4
02.9673.0001 C 17-Sep-02 71
Self Tests
Running Parameter Tests
The luminaire is capable of running self tests by using the TEST menu functions. For
complete details and values for each test refer to “Diagnostic Tests” on page 73.
Note: After 10 seconds of inactivity, the menu display will change to the default state
showing the address.
When running tests on multiple luminaires, a loopback connector is required at the
master luminaire (first in link) and a male termination connector is required at the last
luminaire in the link. (Refer to page 14 for more information regarding the
construction of these connectors.)
Move Disable
The Move option has been added to the test menu. This allows for pan/tilt functions
to be disabled so that the luminaire can be placed in any position for testing without
movement occurring. In order to regain full control of the luminaire, Move will need
to be enabled after testing.
Note: When setting the Move option to disable, luminaires linked by a loopback
connector will have pan and tilt disabled for all the luminaires that are linked.
Termination Connector
Data Thru Data Thru
Master luminaire containing
software version to download
Luminaire 1
requiring update
Luminaire 2
requiring update
Loopback Connector